7×24 服务热线Sales hotline 400-151-0319 厂址Address:河北省邢台市南宫经济开发区Nangong EDZ, Xingtai, Hebei
首页Home/产品中心Products/水浴式气化器Water-bath vaporizer
Electric, steam or hot-water heat source

水浴式气化器Water-bath vaporizer

用热水浴把低温液体加热气化,出力不随气温波动,是北方冬季与高负荷场合的补热主力。Water bath delivers stable output regardless of ambient — the winter trim heater.

3种热源电/蒸汽/热水Heat sources
稳定出力不受气温影响Weather-independent
复热与空温式串接Series with ambient
电加热 / 蒸汽 / 热水该型号现场实拍待补拍,此处不放示意图以免与实物不符No photo of this unit yet; no stand-in image used to avoid mismatch
01 / Overview

产品概述Product overview

水浴式的价值就一条:它不看天气。空温式在 −20℃ 时掉到六成出力,水浴式仍是额定。北方 LNG 站、连续生产的工业用户、以及要求出口温度恒定的场合,水浴式不是备选而是必需。热源三选一:电加热(无锅炉的站点)、蒸汽(有蒸汽源的工厂)、热水(锅炉或余热),换热结构为壳管式或盘管浸没式。A water bath holds rating regardless of weather; heat can be electric, steam or hot water.

设计要点在温控与防冻:出口温度设闭环调节,水温低限联锁停泵,避免低温液体进壳程造成冻结;水箱做保温与补水,户外安装另加防冻排空。Closed-loop outlet temperature control with low-limit interlock and drain-down for outdoor installation.

02 / Structure

结构组成What is on the skid

01
壳体与水箱:保温水箱、壳管或盘管换热面。Insulated bath with shell-and-tube or coil surface.
02
加热元件:电加热管组 / 蒸汽盘管 / 热水盘管。Electric elements, steam or hot-water coils.
03
温控系统:温度传感器 + 调节阀 / 固态继电器。Sensors with control valve or SSR.
04
补水与排空:补水口、排污口、防冻排空阀。Fill, drain and freeze-protection valves.
05
液位与联锁:低液位停机,防干烧。Low-level cut-off against dry firing.
06
撬体与接线:防爆接线盒、接地。Ex junction box, earthing.
03 / Advantages

核心优势Why this design

  • 出力稳定:不受环境温度影响,冬季不降容。Stable output in winter.
  • 三种热源可选:按现场能源条件定,不强制配电。Three heat sources to suit site energy.
  • 与空温式串接:平时空温、峰时水浴,能耗最优。Series with ambient for lowest energy.
  • 温控闭环:出口温度可设定并保持。Closed-loop temperature control.
04 / Specification

技术参数Technical data

热源Heat source电加热 / 蒸汽 / 热水Electric / steam / hot water
换热形式Exchange壳管式 / 盘管浸没式Shell-tube or immersed coil
出口温度Outlet temp.按工况设定,闭环控制Set point, closed loop
适用介质MediumLNG / LO₂ / LN₂ / LAr / CO₂LNG / LO₂ / LN₂ / LAr / CO₂
控制Control温度联锁、低液位停机Temperature interlock, low-level cut-off
安装Mounting室内或户外保温型Indoor or insulated outdoor

表中为该系列典型配置。项目流量、介质与进出口压力不同时按工况单独设计,参数以合同技术文件为准。Typical configuration; units are engineered per duty and the contract data sheet governs.

05 / Duty

适用工况Typical duties

北方 LNG 气化站补热Northern LNG stations连续生产工业用户Continuous industrial users充装站高压气化High-pressure filling出口温度要求恒定的工艺Processes needing constant temperature
07 / Related

同类设备Related equipment

把你的工况发过来,我们出选型表Send your duty, we return a selection sheet

需要提供:介质、最大/最小流量、进口压力、出口压力、现场热源(电/热水/蒸汽)、安装场地条件。We need medium, min/max flow, inlet and outlet pressure, available heat source and site conditions.